Brand: Jiuban
Model: JB5100-H
Name: Automatic wet laser particle size analyzer
一、Product Overview:
JB5100-H is a wet automatic laser particle size analyzer. It adopts the most advanced Mie scattering principle and convergent Fourier transform optical path. The accuracy and repeatability of the test results are guaranteed by high density probe and full range seamless connection test method.
二、The control system schematic diagram is as follows:
Principle Diagram of Control System for Intelligent Laser Particle Size Analyzer
三、Main performance characteristics:★Advanced optical path design: JB5100-H uses convergent Fourier transform testing technology to ensure the maximum range in the shortest focal length, effectively improve the resolution of the instrument; unique high-density detection unit enables 5100-H to have super-strong small particle testing capability, high-density detection unit makes JB5100-H have super-strong seamless testing capability in full range.★Fully Sealed Fiber Semiconductor Laser: JB5100-H uses a highly stable, long-life fully sealed Fiber Semiconductor Laser, excellent stability allows JB5100-H to have a strong test repeatability.★Fully automatic testing: Really automatic testing, what you do is just put in the sample, no interference data need not be selected manually.★Ultrasound anti-dry-burning function: After careful research and development, JB5100-H can realize the function of ultrasonic anti-dry-burning, and avoid★Ultrasound power adjustable: In order to meet the dispersing needs of different samples, JB5100-H achieves ultrasonic power adjustable from 0 to 20 mW. damaging the ultrasound without water.★Dust-proof and shock-proof design: The instrument has been designed as a whole, which greatly improves the service life of internal components. The unique anti-seismic structure can effectively avoid the interference of external vibration to the instrument and make the test results more stable and reliable.★Strong anticorrosive design (selection): According to the actual needs of customers can be equipped with acid, alkali, oil (including all solvent oils), organic solvents (such as acetone, phenol, hexane and all other organic solvents).★Automatic alignment: The combination of mechanical center and optical center is used exclusively. The automatic alignment of optical path is more precise, reaching micron level. At the same time, the speed of optical path adjustment is faster and the fastest is 15 seconds. The self-developed automatic alignment system consists of stepper motor, precise guide rail, precise controller and software system. The minimum step distance is 0.2 micron, which ensures that the focus of the laser beam always passes through the center of the detector, and improves the accuracy of the test results and the repeatability of the test. The automatic alignment system is the standard configuration of all Nike's laser particle sizers.★Unique micro-circulation system: The whole dispersed circulation system has been optimized. The dispersed medium can be circulated for testing when it is more than 120 milliliters, which truly reaches the micro-circulation test. The optimized design ensures that there is no waste night residue after drainage and the accuracy of the next test result. (Microtest is optional)★Exhaust Free Bubble Design: The new design prevents bubbles from entering the test sample window and avoids bubble interference.★Sample non-residue design: The instrument pipeline and drainage structure were optimized. There was no residual liquid in the instrument pipeline and circulating pump to avoid the impact on the next test data.★Sample Window Quick Change Device: A newly designed Sample Window Quick Change Device makes the Sample Window Change more convenient and fast.★Dew point measurement: Fogging in the sample window will affect the accuracy of measurement. Such test results have no practical significance. JB5100-H is equipped with a fogging point measurement system, once fogging software will automatically prompt.四、Main technical parameters:
Specification type | JB5100-H(Gao pin) |
Executive standard | GB/T 19077-2016/ISO 13320:2009 |
Test range | 0.1μm -600μm |
Number of detector channels | 70 |
Accuracy error | <1%(D50 value of national standard sample) |
Repeatability error | <0.5%(D50 value of national standard sample) |
Bubble free | With no exhaust bubbles design, no bubbles interference data more accurate |
Misoperation protection | The instrument has self-protection function of misoperation and does not respond to misoperation. |
Laser parameters | Imported optical fiber output high power semiconductor laser lambda = 635 nm, P > 10 mW |
Optical path calibration | Optical path automatic calibration |
Intelligent operation mode | One-button Automatic Software Operating Mode |
Testing speed | <1 min/time (without sample dispersion time) |
Built-in dispersion method | ultrasonic | Frequency: f = 40KHz, power: P = 80W, time: adjustable at will; with ultrasonic anti-dry burning |
Stir | Integrated design of circulating stirring, speed: 100-33950 RPM speed adjustable |
loop | Circulation rated flow: 0-10L/min adjustable rated power: 25W |
Shading detection | The instrument has the unique function of real-time detection of shading to ensure more accurate sample addition. |
Sample pool | Self-designed boiling sample cell, better dispersion effect, capacity: 190-600 mL can be tested normally. |
Dust and Seismic Design | Dust-proof and shock-proof design for the whole machine |
Microinjection (Selection) | The instrument can be equipped with micro-automatic testing device, 10 milliliters can be circulated testing (optional) |