Products
Home:Product >

JB6100-B Dry-wet granulometer

JB6100-B is the latest product developed by our company, which has won the unanimous praise of our customers since its listing. JB6100-B adopts the most advanced Mie scattering principle and convergent Fourier transform optical path. The accuracy and repeatability of the test results are guaranteed by high density probe and full range seamless connection test method. The unique wet circulation subsystem ensures that there is no particle deposition in the test process and no waste liquid accumulation after drainage, which ensures the accuracy of the second test and makes the test results more reliable. The dry method adopts the linear spray dispersion method, and the sample flies vertically backward after high pressure gas dispersion, avoiding the secondary cluster of the particles to be measured, and at the same time adopts the method of linear spray dispersion. The pipeline has no residue design, which ensures the accuracy of testing different samples. Excellent optical automatic calibration system, dry-wet key switching system, dry computer remote control feeding system, etc. are carefully designed to highlight the unique advantages of JB6100-B.

Detailed
Brand: Jiuban
Model: JB6100-B
Name: Dry-wet granulometer
一、Product Overview:
  JB6100-B is the latest product developed by our company, which has won the unanimous praise of our customers since its listing. JB6100-B adopts the most advanced Mie scattering principle and convergent Fourier transform optical path. The accuracy and repeatability of the test results are guaranteed by high density probe and full range seamless connection test method. The unique wet circulation subsystem ensures that there is no particle deposition in the test process and no waste liquid accumulation after drainage, which ensures the accuracy of the second test and makes the test results more reliable. The dry method adopts the linear spray dispersion method, and the sample flies vertically backward after high pressure gas dispersion, avoiding the secondary cluster of the particles to be measured, and at the same time adopts the method of linear spray dispersion. The pipeline has no residue design, which ensures the accuracy of testing different samples. Excellent optical automatic calibration system, dry-wet key switching system, dry computer remote control feeding system, etc. are carefully designed to highlight the unique advantages of JB6100-B.
二、Main performance characteristics:
Advanced optical path design: JB6100-B uses convergent Fourier transform testing technology to ensure the maximum range in the shortest focal length, effectively improve the resolution of the instrument; unique high-density detection unit, so that 6100-B has super-strong small particle testing ability, high-density detection unit using JB6100-B has super-strong seamless testing ability in the whole range.
Single Optical Path Single Lens Design: The newly designed optical path uses the rear lens acquisition technology, realizes the detection of 0.01 degree to 170 degree without blind area, and the measurement range is 0.01 micron to 2000 micron.
Aluminum alloy optical platform: high-precision all-aluminium alloy optical platform, long-term stability and reliability; optical system is completely closed, effectively solve the problem of dust pollution; instrument design conforms to international laser safety standards, with laser beam automatic protection function.
Misoperation protection function: The newly designed JB6100-B has misoperation protection function, and the instrument has no response function to the operator's wrong instructions. It avoids the damage of the instrument caused by misoperation, and greatly improves the stability of the instrument test results.
Large aperture lens: large aperture Fourier transform lens, more effective to achieve optical signal Fourier transform, more accurate and effective.
Ultrasound anti-drying: JB6100B realizes the function of anhydrous ultrasound self-protection in the sample pool, avoiding damage to the ultrasound, and the ultrasonic power can be adjusted in the range of 0 to 50 watts.
Dust-proof and shock-proof design: The instrument has been designed as a whole, which greatly improves the service life of internal components. The unique suspension structure can effectively avoid the interference of external vibration to the instrument and make the result test more stable and reliable.
Strong anticorrosive design (selection): According to the actual needs of customers can be equipped with acid, alkali, oil (including all solvent oils), organic solvents (such as acetone, phenol, hexane and all other organic solvents).
Imported Fiber Semiconductor Laser: JB6100-B uses imported high-power fiber output semiconductor lasers with high stability and long life. The excellent monochromism and stability make JB6100-B have super repeatability of testing. The laser has the function of self-checking power change and self-adjusting to maintain the constant power output of the laser. (wavelength 635 nm; power greater than 5 mw).
Automatic alignment: The combination of mechanical center and optical center is used exclusively. The automatic alignment of optical path is more precise, reaching micron level. At the same time, the speed of optical path adjustment is faster and the fastest is 15 seconds. The self-developed automatic alignment system consists of stepper motor, precise guide rail, precise controller and software system. The minimum step distance is 0.2 micron, which ensures that the focus of the laser beam always passes through the center of the detector, and improves the accuracy of the test results and the repeatability of the test. The automatic alignment system is the standard configuration of all Nike's laser particle sizers.
Separate design: JB6100-B adopts split design, the optical path part is more stable and effective to avoid the impact of vibration of the dispersing device, greatly improving the repeatability of the instrument test.
Exhaust Free Bubble Design: The new design prevents bubbles from entering the test sample window during the whole test process and avoids bubble interference.
Sample residue-free design: The instrument pipeline and drainage structure were optimized. There was no residual liquid in the instrument pipeline and circulating pump to avoid the impact on the next test data. The dry test also carried out the residue-free design.
Dry computer remote control feeding: In JB6100-B dry test, the tester can control feeding speed by remote computer, which greatly reduces the labor intensity of the tester.
Sample Window Quick Change Device: A newly designed Sample Window Quick Change Device makes the Sample Window Change more convenient and fast.
Software: Complying with GMP of Pharmacopoeia, it has functions of electronic signature, permission setting, data tracing and data non-changeability.
In the pharmaceutical industry, customers can provide 3Q certification.
三、Main technical parameters:
Specification type
JB6100-B
Executive standard
GB/T 19077-2016/ISO 13320:2009
Test range
wet process0.01μm -2000μm

dry process0.1μm -2000μm

Number of detector channels
wet process127
dry process117
Accuracy error
<1%(D50 value of national standard sample)
Repeatability error
<0.5%(D50 value of national standard sample)
Bubble free
With no exhaust bubbles design, no bubbles interference data more accurate
Misoperation protection
The instrument has self-protection function of misoperation and does not respond to misoperation.
Laser parameters
Imported optical fiber output high power semiconductor laser lambda = 650nm, P > 10mW
Camera lens
Imported Canon Lens
Operation mode
One-button Full-automatic Operation of Dry and Wet Process Software
Optical path calibration
Automatic Standard for Optical Path
Wet dispersion method
ultrasonic
Frequency: f = 40KHz, power: P = 80W, time: adjustable at will; with ultrasonic anti-dry burning
Circulation、agitation
Integrated design of circulating stirring, speed: 100-3950 RPM speed adjustable
Circulating flow rate
Circulation rated flow: 0-10L/min adjustable rated power: 25W
Sample pool
Self-designed boiling sample cell, better dispersion effect, capacity: 190-600 mL can be tested normally.
Shading detection
The instrument has the unique function of real-time detection of shading to ensure more accurate sample addition.
Micro injection
The instrument can be equipped with micro-automatic testing device, 10 milliliters can be circulated testing (optional)
dry dispersion
Decentralized mode
High Pressure Air Dispersion
Feeding mode
Vibration Feeding with Mechanical Stepless Speed Regulation and Software Control
Oil-free silent air compressor
Dust filtering function to ensure the accuracy of testing
Cold dryer
Freeze dryer can filter moisture in air to ensure dispersion effect.
software function
Analysis mode
It includes free distribution, R-R distribution, logarithmic normal distribution, and statistical model of classification according to items, etc. It meets the different requirements of different industries for the statistical methods of particle size of tested samples.
Statistical method
Volume distribution and quantity distribution to meet different statistical methods for particle size distribution in different industries
Statistical comparison
It can be used for statistical analysis and comparison of several test results. It can obviously compare the difference of test results of different batches of samples, samples before and after processing and at different time. It has a strong practical significance for the quality control of industrial raw materials.
Self-DIY Display Template
User-defined data to be displayed, according to the percentage of the particle size, according to the percentage of the particle size or according to the particle size interval to find the percentage, in order to meet the different industries on the characterization of particle size testing. Diameter distance, consistency, interval accumulation, etc.
Test report
The test report can export many kinds of documents, such as Word, Excel, Bmp and Text, to meet the requirement of viewing test reports and citing test results in scientific research articles in any occasion.
Multilingual support
Chinese and English language interface support, but also according to user requirements embedded in other language interfaces.
Intelligent operation mode
Really fully automatic operation without human interference, no human interference, you just need to add the sample to be tested according to the prompt, the test results are better repeatability.
Operation mode
Computer operation
Testing speed
<1 min/time (without sample dispersion time)