JB2010-H Dry particle size analyzer

JB2010-H belongs to dry-process automatic laser particle size analyzer, which is widely used in powder industry. Our company has designed different templates for different industries. Customers can choose cement template, abrasive template and so on according to their needs.

Detailed
Brand: Jiuban
Model: JB2010-H
Name: Dry Laser Particle Size Meter
一、Product Overview:
  JB2010-H belongs to dry-process automatic laser particle size analyzer, which is widely used in powder industry. Our company has designed different templates for different industries. Customers can choose cement template, abrasive template and so on according to their needs.
二、Main performance characteristics:
Advanced optical path design: JB2010-H uses convergent Fourier transform testing technology to ensure maximum range in the shortest focal length, effectively improve the resolution of the instrument; unique arrangement of small probes, so that 2010 has a super small particle testing capability. The superior automatic alignment system and computer operating system show the humanized design of JB2010-H.
Highly stable optical path optimization: Unique design gives JB2010-H the most advanced and highly stable optical path. It uses high stability and high power fiber output lasers. Excellent configuration makes JB2010-H have super stability. The main optical path adopts fully closed design, which ensures the instrument to be tested in complex environment for a long time.
96-way simultaneous acquisition motherboard: JB2010-H takes the lead in using 96-way simultaneous acquisition motherboard. All channels collect signals at the same time. The data is more real and reliable. Other manufacturers claim that how many times per second acquisition is a single acquisition of all channels and each channel, and the data is not true.
Special Feeding System for Pharmaceutical Industry: JB2010-H specially developed a special feeding system for pharmaceutical factories. Many traditional vibration feeding materials with low density and light weight are difficult to uniformly feed. The newly developed feeding system is changed from passive feeding to instrument active feeding. The uniform feeding can also ensure the normal testing of very light samples.
Unique dry dispersion system: JB2010-H dispersion system is optimized on the basis of French theoretical data, so that JB2010-H can disperse dry powder more evenly. Super negative pressure ensures the continuity and uniformity of feed, and effectively avoids the cohesion of dry powder in the test process.
Detector: JB2010-H detector adopts a new design which combines the main detector with the sub-detector, which ensures the seamless detection in the whole range of the instrument and makes the test more accurate. The main detector has designed an automatic alignment system, which can realize the automatic alignment of one key of the instrument and highlight the humanized design. Meanwhile, the damage of manual alignment to the detector is effectively avoided, and the service life of the instrument is effectively prolonged.
Dust-proof and shock-proof design: The instrument has been designed as a whole, which greatly improves the service life of internal components. The unique suspension structure can effectively avoid the interference of external vibration to the instrument and make the result test more stable and reliable.
Optical path auto-calibration: Exclusive use of mechanical center and optical center technology, optical path auto-alignment positioning is more accurate, reaching micron level; at the same time, optical path adjustment speed is faster and fastest 15 seconds can complete the adjustment. The self-developed automatic alignment system consists of stepper motor, precise guide rail, precise controller and software system. The minimum step distance is 0.2 micron, which ensures that the focus of the laser beam always passes through the center of the detector, and improves the accuracy of the test results and the repeatability of the test. The automatic alignment system is the standard configuration of all Nike's laser particle sizers.
No residue in the pipeline: There is no residue sample in the pipeline after the test, which will not interfere with the next test.
Computer-controlled feeding: Testers can precisely control the amount of feeding by means of computers.
Software: Complying with GMP of Pharmacopoeia, it has functions of electronic signature, permission setting, data tracing and data non-changeability.
三、Main technical parameters:
Specification type
JB2010-H
Executive standard
ISO   13320-1:1999;GB/T19077.1-2008
Test range
0.1μm -2000μm
Number of detector channels
108
Accuracy error
<1%(D50 value of national standard sample)
Repeatability error
<1%(D50 value of national standard sample)
Repeatability error
High Precision Adjusting Vibration Feeding to Guarantee Uniform Feeding in Testing Process
Misoperation protection
The instrument has self-protection function of misoperation and does not respond to misoperation.
Laser parameters
Imported high power fiber laser with output lambda = 650nm, P > 10mW
Dispersing method
High Pressure Air Turbulence Dispersion

software

 function

Analysis mode

It includes free distribution, R-R distribution, logarithmic normal distribution, and statistical model of classification

 according to items, etc. It meets the different requirements of different industries for the statistical methods of particle size of tested samples.

Statistical method

Volume distribution and quantity distribution to meet different statistical methods for particle size distribution in different industries

Statistical comparison

It can be used for statistical analysis and comparison of several test results. It can obviously compare the difference of test results of different batches of samples,

 samples before and after processing and at different time. It has a strong practical significance for the quality control of industrial raw materials.

Self-made DIY template

User-defined data to be displayed, according to the percentage of the particle size, according to the percentage of the particle size or according to the 

particle size interval to find the percentage, in order to meet the different industries on the characterization of particle size testing. Diameter distance, consistency, interval accumulation, etc.

Test report
The test report can export many kinds of documents, such as Word, Excel, Bmp and Text, to meet the requirement of viewing test reports and citing test results in scientific research articles in any occasion.
Multilingual support
Chinese and English language interface support, but also according to user requirements embedded in other language interfaces.
Intelligent operation mode
Really fully automatic operation without human interference, no human interference, you just need to add the sample to be tested according to the prompt, the test results are better repeatability.
Operation mode
Computer operation
Testing speed
<1min/次(excluding sample dispersion time)
size
980mm*410mm*450mm